BULLETIN NUMBER:  SWB-032

DATE ISSUED:  October 30, 2003

DATE CLOSED:  April 5, 2005

AFFECTED SYSTEMS:  Power Hawk Series 700/900

RELEASE LEVEL:  Power Hawk System Level Diagnostics Revision 9.7  (PowerIO)

 

EXPLANATION:  If all the eti devices and pig devices are configured to run concurrently within the Power Hawk System Level Diagnostic (PowerIO) Revision 9.7 then the eti devices will report errors similar to the following:

 

*** ERROR
*** Test 'rcim.reti eti03' (pid 22939) failed cycle 20440 on Thu Jun 19 10:49:21

*** Exit status was 1, mode bits: 0x100.
*** Test 'rcim.reti eti03' has failed 0 times previously.
*** Description of failure:
*** RCIM PMC (1578845)  Edge Triggered & PIG Interrupt Test
*** ETI device: /dev/reti/eti03
*** If running the PIG test, make sure turn around cable is installed on RCIM PMC ***
*** Case: clear, arm, disable, request, enable
*** ERROR: Interrupt NOT received on: /dev/reti/eti03 count = 97  

 

RESOLUTION:  The eti and pig devices should not be configured to run concurrently.  They must be run separately from one another.  PIG devices must be tested individually to avoid errors. This problem has been fixed in the next release of the Power Hawk System Level Diagnostics Revision 9.8, which is currently being developed and tested.